当前位置:首页-新闻资讯

太阳能光伏发电系统接地目的以及类型要求

发布时间:2023-02-21 发布人:金佰利中国·种电 发布来源://tianjibiotech.com/
太阳能光伏发电系统接地的主要目的
Main purpose of grounding of solar photovoltaic power generation system
(1)将低压电气设备的中性点接地,以此来降低电气设备的绝缘水平要求,抑制因系统故障接地而引起的过电压。
(1) The neutral point of low-voltage electrical equipment is grounded to reduce the insulation level requirements of electrical equipment and suppress overvoltage caused by system fault grounding.
(2)防止用电设备由于绝缘老化、损坏引起触电、火灾等事故。
(2) Prevent electric shock, fire and other accidents caused by aging and damage of insulation of electrical equipment.
(3)保证防雷器件在电气设备遭受雷击时更有效的保护设备。
(3) Ensure that lightning protection devices can protect electrical equipment more effectively when it is struck by lightning.
(4)降低系统的电磁干扰。
(4) Reduce the electromagnetic interference of the system.
太阳能光伏发电系统的接地类型和要求
Grounding type and requirements of solar photovoltaic power generation system
(1)防雷接地,包括避雷针(带)、引下线、接地体等,要求接地电阻小于10Ω,并建议考虑单独设置接地体。
(1) Lightning protection grounding, including lightning rod (strip), down lead, grounding body, etc., requires the grounding resistance to be less than 10 Ω, and it is recommended to consider setting a separate grounding body.
(2)工作接地,包括逆变器、蓄电池组的中性点、电压互感器和电流互感器的二次线圈等,接地电阻小于等于4Ω。
(2) Working grounding, including the neutral point of the inverter and storage battery, the secondary coil of voltage transformer and current transformer, and the grounding resistance is less than or equal to 4 Ω.
(3)安全保护接地,包括光伏组件外框、支架,控制器、逆变器、配电柜外壳,蓄电池支架、电缆外皮、金属穿线管外皮等,要求接地电阻小于等于4Ω。
(3) Safety protection grounding, including PV module frame, support, controller, inverter, distribution cabinet shell, battery support, cable cover, metal conduit cover, etc., requires the grounding resistance to be less than or equal to 4 Ω.
太阳能光伏发电
(4)光伏发电系统中常用的接地方法如图所示,其中无接地就是光伏发电系统没有接地装置。
(4) The common grounding methods in the photovoltaic power generation system are shown in the figure, in which no grounding means that the photovoltaic power generation system has no grounding device.
(5)条件许可时,防雷接地系统应尽量单独设置,不与其它接地系统共用,并保证防雷接地系统的接地体与公用接地体在地下的距离保持在3m以上。
(5) When conditions permit, the lightning protection grounding system should be set separately as far as possible, not shared with other grounding systems, and the distance between the grounding body of the lightning protection grounding system and the public grounding body should be kept at more than 3m underground.
(6)系统接地
(6) System grounding
系统接地是指将光伏发电系统中的一路导线(例如光伏组串负极输出引线),连接到设备接地端的接地方式。系统接地的重要作用是当系统工作正常时,它能够稳定电气系统对地的电压,还能在发生故障时,使过电流装置更容易运行。
System grounding refers to the grounding method of connecting a circuit of conductors in the photovoltaic power generation system (such as the negative output lead of the photovoltaic string) to the equipment grounding terminal. The important role of system grounding is that when the system works normally, it can stabilize the voltage of the electrical system to the ground, and also make the overcurrent device easier to operate in case of fault.
系统中点接地是指在直流输出为三线输出时,将中性线或中心抽头接。
The neutral point grounding of the system refers to connecting the neutral line or center tap when the DC output is three-wire output.
land
当实际施工中采用系统接地方式时,二线系统中的一根导线,或三线系统中的中性线要按照下列方法牢固接地。
When the system grounding method is adopted in the actual construction, one conductor in the two-wire system or the neutral wire in the three-wire system shall be firmly grounded according to the following methods.
①直流电路可以在光伏方阵输出电路的任意一点上接地,但接地点要尽可能靠近光伏组件前端,在开关、熔断器、保护二极管等之前,以更好地保护系统免遭雷击引起的电压冲击。
① The DC circuit can be grounded at any point of the output circuit of the PV array, but the grounding point should be as close as possible to the front end of the PV module, before the switch, fuse, protective diode, etc., to better protect the system from the voltage impact caused by lightning strikes.
②当从组串或方阵中拆去任何一块组件时,系统接地、设备接地都不应该被切断。
② When any component is removed from the string or square array, the system grounding and equipment grounding should not be cut off.
③直流电路的地线和设备的地线应共用同一接地电极。如果是中性接地,要把此地线与供电设施干线的中性地线连接。直流系统与交流系统的所有地线应该是共同的。
③ The ground wire of DC circuit and equipment shall share the same grounding electrode. If it is neutral grounding, connect this ground wire with the neutral ground wire of the power supply facility trunk line. All ground wires of DC system and AC system shall be common.
光伏发电安全运行的主要环节,在设计、施工和运行维护过程中都要引起足够的重视,确保接地良好,才能确保电站安全运行。更多相关内容就来我们网站//tianjibiotech.com咨询!
The main links of safe operation of photovoltaic power generation should be paid enough attention in the process of design, construction and operation and maintenance to ensure good grounding to ensure safe operation of the power station. Come to our website for more relevant content //tianjibiotech.com consulting service